本文共 373 字,大约阅读时间需要 1 分钟。
zabbix3.2版本升级到zabbix3.4版本后打开页面报错,报错内容如下
Database error
The frontend does not match Zabbix database. Current database version (mandatory/optional): 3020000/3020000. Required mandatory version: 3040000. Contact your system administrator.解决办法:
进入数据库
mysql> show databases; mysql> use zabbix; mysql> update dbversion set mandatory=3040000; mysql> flush privileges;重新打开web即可解决
转载地址:http://qkrlo.baihongyu.com/